On a commercial low-slope roof in Colorado Springs, the rooftop HVAC unit is often the busiest and most leak-prone spot on the building. Every rooftop unit (RTU) sits on a curb that cuts through the roof, gets visited by service techs, and takes the full force of snow drifts, hail, and freeze-thaw. When water shows up on a ceiling tile under a unit, the cause might be the roof, the unit itself, or the way the two were tied together. This guide helps facility managers and owners sort out rooftop HVAC curb leaks: where they start, how to tell a roof leak from an HVAC leak, and what a lasting repair looks like.
Tectum Roofing’s office is at 770 Wooten Road, Suite 105, Colorado Springs, CO 80915, and we answer 24/7 at 719-455-7663. Colorado Springs is our primary service area. We also serve Denver, Pueblo, Parker, Castle Rock, Fort Collins, Breckenridge, Grand Junction, and Durango as service areas. Those are service areas, not separate offices.
Why rooftop units leak so often
An HVAC curb is a raised frame that the unit sits on, with the roof membrane flashed up its sides. That detail has more seams, corners, and transitions than almost anywhere else on the roof, and it is surrounded by activity. Common reasons it fails:
- Curb flashing failure. The membrane flashing that runs up the curb can pull loose, split at the corners, or lose adhesion over years of thermal movement and UV at altitude.
- Flashing that is too short. When the roof has been recovered or the insulation is thicker than the original, the curb may not leave enough height for proper flashing. Manufacturers specify minimum flashing heights for a reason: drifting snow and ponded water sit higher than you think.
- Failed counterflashing or curb cap. The metal that covers the top of the flashing, and the joint between the unit and the curb, can loosen or lose its seal.
- Water ponding on the uphill side. A large curb acts like a dam. Without a cricket to divert water around it, water and slush collect against the curb and look for any opening.
- Foot traffic and service damage. Dropped screws, sheet-metal scraps, tools, and panels set on the membrane can puncture or cut it near the unit.
- Unit swaps and curb adapters. When a new RTU replaces an old one, an adapter curb or a new curb may be installed. If the roofing side of that change is not done by someone tying it into the roof system correctly, it becomes a weak point.
Is it the roof or the HVAC unit?
Not every leak under an RTU is a roofing problem. Before anyone cuts into the membrane, it helps to think about when the water shows up:
- Leaks only when it rains or snow melts usually point to the roof: curb flashing, counterflashing, nearby seams, or ponding against the curb.
- Leaks when the unit is running in cooling season, even in dry weather, often point to the unit: a clogged condensate drain, a cracked drain pan, or a condensate line that discharges onto the roof in the wrong place.
- Leaks during wind-driven rain or snow can come through unit panels, louvers, or the joint between the unit and the curb, which is outside the roof membrane.
- Leaks inside the ductwork or at the supply diffuser may mean water is getting into the unit or the duct opening inside the curb.
The fastest answers come when the roofer and the HVAC contractor compare notes. A proper investigation looks at the curb detail, the membrane around it, the unit’s drain and panels, and the leak history together. Our commercial roof leak repair guide explains how a leak investigation works on low-slope roofs.
Colorado Springs conditions that make curbs worse
- Snow drifts. Wind piles snow against rooftop units and screens. Those drifts melt from the top in the afternoon sun and refreeze at night, which works water into every gap at the curb. See our commercial roof snow guide.
- Freeze-thaw cycles. Water that gets behind loose flashing expands when it freezes and opens the gap a little more each time.
- Hail. Hail can bruise membrane flashing and dent curb caps and unit panels. After a storm, check around rooftop equipment as well as the open field. Our commercial hail damage guide covers what to look for.
- High-altitude UV. Sun exposure ages flashing and sealants faster, especially on the south and west faces of a curb.
What a lasting curb repair should include
Sealant smeared over the corner of a curb might stop a drip for a while, but it rarely lasts through a Colorado winter. A real repair proposal should cover:
- The confirmed source, with photos, so you know it was the curb and not the unit.
- Removing failed flashing and installing new flashing that is compatible with your roof system, whether that is TPO, EPDM, PVC, or modified bitumen.
- Reinforced corners, since corners are where curb flashing most often splits.
- Counterflashing or curb cap work so the top edge of the flashing is protected.
- Checking for wet insulation around the curb and cutting out and replacing saturated material, so trapped water does not keep feeding the leak.
- Drainage around the curb, including a cricket on the uphill side when water ponds against it.
- Walkway pads on the service path to the unit, so techs are not walking and kneeling directly on the membrane.
Our commercial roof flashing repair guide covers flashing details across the roof, including penetrations and walls.
For leaks beyond the curbs, see our commercial roof repair services in Colorado Springs for TPO, PVC, EPDM and metal roofs.
Planning an RTU replacement with your roofer
If a unit is being replaced or added, bring the roofer in early, not after the crane leaves. A good plan covers:
- Who owns which scope. The HVAC contractor sets and connects the unit; the roofer handles curb flashing and the membrane tie-in. Write that down.
- Curb height and fit. Make sure the new curb or adapter leaves room for proper flashing above the finished roof surface.
- Abandoned openings. Old curbs and openings that are no longer used should be removed and the roof patched properly, not left as low curbs waiting to leak.
- Warranty protection. If the roof is under a manufacturer warranty, new penetrations and curb work usually need to be done in a way that keeps that coverage intact. Check before work starts.
- Roof protection during the work. Staging, crane picks, and heavy equipment on the roof can damage the membrane if it is not protected.
Keeping curbs from becoming the next leak
Most curb leaks start small and are easy to catch on a scheduled inspection: a loose corner, a gap at the counterflashing, a puncture next to a service panel. Tectum’s Roof Asset Management (RAM) program offers Silver, Gold, and Platinum levels of scheduled inspection and maintenance, including rooftop equipment areas, so problems like these get handled before they reach the ceiling. Our commercial roof inspection checklist shows what a full inspection covers.
When a roof has many units and keeps leaking at several of them, it may be a sign the system is near the end of its life. Our commercial roof replacement guide explains when it makes sense to stop repairing and plan a replacement, which is also the best time to rebuild every curb detail correctly. On commercial jobs, Tectum can provide manufacturer NDL (no dollar limit) warranty options where the project qualifies; terms depend on the manufacturer and system and are reviewed project by project.
Frequently asked questions
Why does my roof only leak under the HVAC unit in summer?
If it leaks in dry weather while the unit is cooling, the likely cause is the unit’s condensate drain or drain pan rather than the roof. Have your HVAC contractor check it. If it leaks during rain or snowmelt, the curb flashing or the area around the curb is more likely.
Can a curb leak be fixed with sealant?
Sealant can be a short-term stopgap in an emergency, but it is not a lasting repair. A lasting fix replaces failed flashing with materials compatible with your roof system and protects the top edge with counterflashing.
Who is responsible for a leak at a new rooftop unit, the roofer or the HVAC contractor?
It depends on who did the curb and flashing work. That is why scopes should be written down before a unit is replaced. If you are not sure, a roofer can inspect the detail and document what failed.
Do snow drifts around rooftop units cause leaks?
They can. Drifts hold melting snow against the curb, and freeze-thaw cycles work water into any gap in the flashing. Flashing height, a cricket on the uphill side, and keeping drains clear all help.
Will new rooftop equipment affect my roof warranty?
It can. Many manufacturer warranties require that new penetrations and curbs be flashed in an approved way. Check your warranty and talk to your roofer before the work is scheduled.
Do you handle emergency leaks at rooftop units?
Yes. Tectum answers 24/7 at 719-455-7663 for active leaks in Colorado Springs and our other service areas.
Get your rooftop units checked
If water is showing up under a rooftop unit, or you have equipment changes coming up, call Tectum Roofing 24/7 at 719-455-7663 or contact us to request an inspection. Learn more about our commercial roofing services and the areas we serve.